      This study was carried out to measure diameters of stents within phantom and to know proper algorithm for evaluating patency of stent by using multi-detector computed tomography (MDCT). Phantom model that stent was located in plastic pite with mixed s...

      This study was carried out to measure diameters of stents within phantom and to know proper algorithm for evaluating patency of stent by using multi-detector computed tomography (MDCT). Phantom model that stent was located in plastic pite with mixed saline and contrast (10:1) and total 80 patients (man:woman = 53:27, mean age, 60.8 years old) who undertaken percutaneous coronary intervention (stenting) were included in this study. Computed tomography scans were performed with 16- and 64-slice MDCT scanner with retrospective electrocardiography gating. Standard scanning protocols were applied. Cardiac radiologist and radiologic technician measured internal diameters of stents. Also, image qualities of stents as 8 points were scored. For evaluation of images,window width and window center were used as 900±100 and 400±100, respectively. In phantom model, average maximal diameters measured by each algorithms were 2.35 mm (B50f in Siemens AG, Medical Solutions [S company]) and 2.53 mm (Xres standard [XCB] in Phillips Medical Systems [P company]), respectively. In patients, in-stent resolution processed by Xres sharp (XCC)was scored as 7.67 (highest). In this study, B40f, B50f (16 slice MDCT in S company), XCB and XCC (64 slice MDCT in P company) are appropriate algorithms for evaluating internal patency of stents.

      더보기

      참고문헌 (Reference) 논문관계도

      1 이철주, "좌내흉동맥과 복재정맥편을 사용한 관상동맥우회로술 환자에서의 추적조사에서 MDCT의 유용성" 대한흉부외과학회 38 (38): 410-414, 2005

      2 Mahnken AH, "Value of 3D-volume rendering in the assessment of coronary arteries with retrospectively ECG-gated multislice spiral CT" (44) : 302-309, 2003

      3 Juergens KU, "Using ECG-gated multidetector CT to evaluate global left ventricular myocardial function in patients with coronary artery disease" (179) : 1545-1550, 2002

      4 Lemos PA, "Unrestricted utilization of sirolimus-eluting stents compared with conventional bare stent implantation in the “real world”: the Rapamycin- Eluting Stent Evaluated At Rotterdam Cardiology Hospital (RESEARCH) registry" (109) : 190-195, 2004

      5 Mochizuki T, "Two- and three-dimensional CT ventriculography: a new application of helical CT" (174) : 203-208, 2000

      6 Vogl TJ, "Techniques for the detection of coronary atherosclerosis: multi-detector row CT coronary angiography" (223) : 212-220, 2002

      7 Nieman K, "Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography" (106) : 2051-2054, 2002

      8 Giesler T, "Noninvasive visualization of coronary arteries using contrast-enhanced multidetector CT: influence of heart rate on image quality and stenosis detection" (179) : 911-916, 2002

      9 Rumberger JA, "Noninvasive coronary angiography using computed tomography: ready to kick it up another notch?" (106) : 2036-2038, 2002

      10 Nieman K, "Non-invasive coronary angiography with multislice spiral computed tomography: impact of heart rate" (88) : 470-474, 2002

      1 이철주, "좌내흉동맥과 복재정맥편을 사용한 관상동맥우회로술 환자에서의 추적조사에서 MDCT의 유용성" 대한흉부외과학회 38 (38): 410-414, 2005

      2 Mahnken AH, "Value of 3D-volume rendering in the assessment of coronary arteries with retrospectively ECG-gated multislice spiral CT" (44) : 302-309, 2003

      3 Juergens KU, "Using ECG-gated multidetector CT to evaluate global left ventricular myocardial function in patients with coronary artery disease" (179) : 1545-1550, 2002

      4 Lemos PA, "Unrestricted utilization of sirolimus-eluting stents compared with conventional bare stent implantation in the “real world”: the Rapamycin- Eluting Stent Evaluated At Rotterdam Cardiology Hospital (RESEARCH) registry" (109) : 190-195, 2004

      5 Mochizuki T, "Two- and three-dimensional CT ventriculography: a new application of helical CT" (174) : 203-208, 2000

      6 Vogl TJ, "Techniques for the detection of coronary atherosclerosis: multi-detector row CT coronary angiography" (223) : 212-220, 2002

      7 Nieman K, "Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography" (106) : 2051-2054, 2002

      8 Giesler T, "Noninvasive visualization of coronary arteries using contrast-enhanced multidetector CT: influence of heart rate on image quality and stenosis detection" (179) : 911-916, 2002

      9 Rumberger JA, "Noninvasive coronary angiography using computed tomography: ready to kick it up another notch?" (106) : 2036-2038, 2002

      10 Nieman K, "Non-invasive coronary angiography with multislice spiral computed tomography: impact of heart rate" (88) : 470-474, 2002

      11 Kopp AF, "Non-invasive coronary angiography with high resolution multidetectorrow computed tomography. Results in 102 patients" (23) : 1714-1725, 2002

      12 Song MH, "Multidetector computed tomography versus coronary angiogram in evaluation of coronary artery bypass grafts" (79) : 585-588, 2005

      13 Treede H, "Multidetector computed tomography (MDCT) in coronary surgery: first experiences with a new tool for diagnosis of coronary artery disease" (74) : 1398-1402, 2002

      14 Juergens KU, "Multi-detector row computed tomography of the heart: does a multisegment reconstruction algorithm improve left ventricular volume measurements?" (15) : 111-117, 2005

      15 Juergens KU, "Multi-detector row CT of left ventricular function with dedicated analysis software versus MR imaging: initial experience" (230) : 403-410, 2004

      16 Reagan K, "Introduction to coronary arteriography" (32) : 419-433, 1994

      17 Sigwart U, "Intravascular stents to prevent occlusion and restenosis after transluminal angioplasty" (316) : 701-706, 1987

      18 Windecker S, "Interventional cardiology in Europe 1995. Working Group Coronary Circulation of the European Society of Cardiology" (20) : 484-495, 1999

      19 Gerber TC, "Image quality in a standardized algorithm for minimally invasive coronary angiography with multislice spiral computed tomography" (27) : 62-69, 2003

      20 Ross R, "Heart disease: a textbook of cardiovascular medicine. 5th ed" Saunders 1105-1125, 1997

      21 Al Suwaidi J, "Do stents reduce mortality compared with balloon angioplasty? A critical review of all the evidence" (150) : 7-10, 2005

      22 Achenbach S, "Detection of coronary artery stenoses by contrast-enhanced, retrospectively electrocardiographically-gated, multislice spiral computed tomography" (103) : 2535-2538, 2001

      23 Kopp AF, "Coronary arteries: retrospectively ECG-gated multi-detector row CT angiography with selective optimization of the image reconstruction window" (221) : 683-688, 2001

      24 Yamamuro M, "Cardiac functional analysis with multi-detector row CT and segmental reconstruction algorithm: comparison with echocardiography, SPECT, and MR imaging" (234) : 381-390, 2005

      25 Seifarth H, "Assessment of coronary artery stents using 16-slice MDCT angiography: evaluation of a dedicated reconstruction kernel and a noise reduction filter" (15) : 721-726, 2005

      26 Korea National Statistical Office, "Annual report on the cause of death statistics (based on vital registration)" Korea National Statistical Office 2002

      27 Serruys PW, "A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease. Benestent Study Group" (331) : 489-495, 1994