Purpose: To compare postoperative vision, high‐order aberrations, contrast sensitivity, power of accommodation, and depth of focus of monofocal aspheric (TECNIS ZA9003) and multifocal aspheric (TECNIS ZM900) intraocular lenses (IOL). Methods: Th...
http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
https://www.riss.kr/link?id=A100523536
윤종억 (연세대학교) ; 정재림 (연세대학교) ; 홍진표 (연세대학교) ; 하병진 (실로암 안과병원) ; 김태임 (연세대학교) ; 김응권 (연세대학교) ; Jong Uk Yoon ; MD ; Jae Lim ; Chung ; MD ; Jin Pyo Hong ; MD ; Byoung Jin Ha ; MD ; Tae-im Kim ; MD ; Eung Kweon Kim ; MD ; PhD
2009
-
Aspheric ; Diffractive ; Multifocal ; TECNIS
510
KCI등재,SCOPUS,ESCI
학술저널
195-201(7쪽)
13
0
상세조회0
다운로드다국어 초록 (Multilingual Abstract)
Purpose: To compare postoperative vision, high‐order aberrations, contrast sensitivity, power of accommodation, and depth of focus of monofocal aspheric (TECNIS ZA9003) and multifocal aspheric (TECNIS ZM900) intraocular lenses (IOL). Methods: Th...
Purpose: To compare postoperative vision, high‐order aberrations, contrast sensitivity, power of accommodation, and depth of focus of monofocal aspheric (TECNIS ZA9003) and multifocal aspheric (TECNIS ZM900) intraocular lenses (IOL). Methods: Thirty‐four eyes which received intraocular lens implantation in the posterior chamber were equally divided into two groups: TECNIS ZA9003 (17 eyes) and TECNIS ZM900 (17 eyes). Before and three months after surgery, visual acuities at near, intermediate, and far distances, and depth of focus were recorded. High order aberrations, spherical aberrations and accommodation power were measured with iTrace, and contrast sensitivity was evaluated using Optec 6500. An independent T‐test analysis was used to compare the two groups. Results: There were no significant differences of high order aberrations, spherical aberrations, accommodation power, or distance vision between the two groups at three months postoperatively. The multifocal IOL (TECNIS ZM900) group revealed better intermediate and near vision (p<0.01) and deeper depth of focus, and lower contrast sensitivities (p=0.03) than the monofocal IOL group. Conclusions: There was no difference in accommodation power between the two groups, but multifocal TECNIS ZM900 IOL exceeds monofocal TECNIS ZA9003 IOL in intermediate and near vision due to diffractive lens design and less spherical aberration by its asphericity.
참고문헌 (Reference)
1 이준모, "단초점과 다초점 인공수정체안의 광학수차와 대비감도의 비교" 대한안과학회 43 (43): 1882-1886, 2002
2 최혜선, "단안의 다중초점 인공수정체 삽입 후의 임상 결과" 대한안과학회 42 (42): 702-708, 2001
3 Monte´s-Mico´ R, "Visual performance with multifocal intraocular lenses mesopic contrast sensitivity under distance and near conditions" 111 : 85-96, 2004
4 Toto L, "Visual performance and biocompatibility of 2 multifocal diffractive IOLs" 33 : 1419-1425, 2007
5 Simpson MJ, "The diffractive multifocal intraocular lens" 1 : 115-121, 1989
6 Im YW, "The difference of the near visual acuity between multifocal IOL and monofocal IOL" 35 : 1027-1032, 1994
7 Kang SG, "The Effect of Illumination on Visual Acuity and Visual Field in Eyes with Multifocal Intraocular Lens" 35 : 78-82, 1994
8 Rocha KM, "Spherical Aberration and Depth of Focus in Eyes Implanted with Aspheric and Spherical Intraocular Lenses" 114 : 2050-2054, 2007
9 Pineda-Fernández A, "Refractive outcomes after bilateral multifocal intraocular lens implantation" 30 : 685-688, 2004
10 Goes FJ, "Refractive lens exchange with the diffractive multifocal TECNIS ZM900 intraocular lens" 24 : 243-250, 2008
1 이준모, "단초점과 다초점 인공수정체안의 광학수차와 대비감도의 비교" 대한안과학회 43 (43): 1882-1886, 2002
2 최혜선, "단안의 다중초점 인공수정체 삽입 후의 임상 결과" 대한안과학회 42 (42): 702-708, 2001
3 Monte´s-Mico´ R, "Visual performance with multifocal intraocular lenses mesopic contrast sensitivity under distance and near conditions" 111 : 85-96, 2004
4 Toto L, "Visual performance and biocompatibility of 2 multifocal diffractive IOLs" 33 : 1419-1425, 2007
5 Simpson MJ, "The diffractive multifocal intraocular lens" 1 : 115-121, 1989
6 Im YW, "The difference of the near visual acuity between multifocal IOL and monofocal IOL" 35 : 1027-1032, 1994
7 Kang SG, "The Effect of Illumination on Visual Acuity and Visual Field in Eyes with Multifocal Intraocular Lens" 35 : 78-82, 1994
8 Rocha KM, "Spherical Aberration and Depth of Focus in Eyes Implanted with Aspheric and Spherical Intraocular Lenses" 114 : 2050-2054, 2007
9 Pineda-Fernández A, "Refractive outcomes after bilateral multifocal intraocular lens implantation" 30 : 685-688, 2004
10 Goes FJ, "Refractive lens exchange with the diffractive multifocal TECNIS ZM900 intraocular lens" 24 : 243-250, 2008
11 Sen HN, "Quality of vision after AMO Array multifocal intraocular lens implantation" 30 : 2483-2493, 2004
12 Leyland MD, "Prospective randomised double-masked trial of bilateral multifocal, bifocal or monofocal intraocular lenses" 16 : 481-490, 2002
13 Rossetti L, "Performance of diffractive multifocal intraocular lenses in extracapsular cataract surgery" 30 : 124-128, 1994
14 Walkow L, "Patient satisfaction after implantation of diffractive designed multifocal intraocular lenses in dependence on objective parameters" 239 : 683-687, 2001
15 Barbero S, "Optical aberrations of intraocular lenses measured in vivo and in vitro" 20 : 1841-1851, 2003
16 Claoue´C, "Multifocal intraocular lenses" 34 : 217-237, 2002
17 Hütz WW, "Intermediate vision and reading speed with array, TECNIS, and ReSTOR intraocular lenses" 24 : 251-256, 2008
18 Schmidinger G, "Depth of focus in eyes with diffractive bifocal and refractive multifocal intraocular lenses" 32 : 1650-1656, 2006
19 Schmitz S, "Contrast sensitivity and glare disability by halogen light after monofocal and multifocal lens implantation" 84 : 1109-1112, 2000
20 Kamlesh, Dadeya S, "Contrast sensitivity and depth of focus with aspheric multifocal versus conventional monofocal intraocular lens" 36 : 197-201, 2001
21 Weghaupt H, "Comparison of pseudoaccommodation and visual quality between a diffractive and refractive multifocal intraocular lens" 24 : 663-665, 1998
22 Allen ED, "Comparison of a diffractive bifocal and a monofocal intraocular lens" 22 : 446-451, 1996
23 Heo JY, "Clinical results of AMO ARRAY multifocal intraocular lens" 40 : 978-986, 1999
24 Kim YS, "Clinical experience of 3M multifocal intraocular lens implantation" 31 : 1308-1317, 1990
25 Javitt JC, "Cataract extraction with multifocal intraocular lens implantation: a multinational clinical trial evaluating clinical, functional, and quality-of-life outcomes" 107 : 2040-2048, 2000
26 Steinert RF, "A prospective, randomized, double-masked comparison of a zonal-progressive multifocal intraocular lens and a monofocal intraocular lens" 99 : 853-860, 1992
27 Song MJ, "A Clinical study of 3M multifocal intraocular lens implant" 32 : 234-240, 1991
개방각녹내장환자의 황반 망막 및 시신경유두주위 망막신경섬유층 두께와 시야변화와의 상관관계
동일한 최소량의 하사근후전술에 따른 상사근마비의 치료효과
학술지 이력
연월일 | 이력구분 | 이력상세 | 등재구분 |
---|---|---|---|
2023 | 평가예정 | 해외DB학술지평가 신청대상 (해외등재 학술지 평가) | |
2020-01-01 | 평가 | 등재학술지 유지 (해외등재 학술지 평가) | |
2017-01-01 | 평가 | 등재학술지 유지 (계속평가) | |
2013-01-01 | 평가 | 등재 1차 FAIL (등재유지) | |
2010-01-01 | 평가 | 등재학술지 유지 (등재유지) | |
2007-01-01 | 평가 | 등재학술지 선정 (등재후보2차) | |
2006-01-01 | 평가 | 등재후보 1차 PASS (등재후보1차) | |
2005-01-01 | 평가 | 등재후보학술지 유지 (등재후보1차) | |
2003-01-01 | 평가 | 등재후보학술지 선정 (신규평가) |
학술지 인용정보
기준연도 | WOS-KCI 통합IF(2년) | KCIF(2년) | KCIF(3년) |
---|---|---|---|
2016 | 0.22 | 0.22 | 0.22 |
KCIF(4년) | KCIF(5년) | 중심성지수(3년) | 즉시성지수 |
0.23 | 0.23 | 0.366 | 0.02 |