      Are Portable Imaging Intraoperative Radiographs Helpful for Assessing Adequate Acetabular Cup Positioning in Total Hip Arthroplasty?

      한글로보기

      https://www.riss.kr/link?id=A104778081

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Despite advances in surgical techniques and instrumentation, current intra-operative estimations of acetabular version in total hip arthroplasty are of limited accuracy. In the present study, two experienced orthopedic surgeons compared intra-operat...

      Despite advances in surgical techniques and instrumentation, current intra-operative

      estimations of acetabular version in total hip arthroplasty are of limited accuracy.

      In the present study, two experienced orthopedic surgeons compared intra-operatively

      measured (using portable imaging) anteversions and vertical inclinations of

      acetabular components with those measured using standardized radiographs postoperatively

      in 40 patients. Of the all vertical inclinations measured from intra-operative

      radiographs, 72.5% (n=29) were within ±2°, and 97.5% (n=39) were within

      ±5° of those determined using post-operative radiographs, and for anteversion,

      52.5% (n=21) were within ±2°, and 97.5% (n=39) were within ±5°. Post-operative

      radiographs demonstrated that 90.0% (n=36) of vertical inclinations and anteversions

      were within the adequate zone. Obviously, our method has its limitations,

      but the authors conclude that the method described in this article better allows surgeons

      to verify acetabular version intra-operatively. In particular, the described

      method is suitable in cases with a deformed acetabular anatomy and difficult revision

      surgery.

      더보기

      참고문헌 (Reference)

      1 D’Lima DD, "The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios" 82 : 315-321, 2000

      2 Kummer FJ, "The effect of acetabular cup orientations on limiting hip rotation" 14 : 509-513, 1999

      3 McLaren RH, "Prosthetic hip angulation" 107 : 705-706, 1973

      4 Carlsson AS, "Postoperative dislocation in the Charnley and Brunswik total hip arthroplasty" 125 : 177-182, 1977

      5 Garcia-Cimbrelo E, "Munuera L. Dislocation in low-friction arthroplasty" 7 : 149-155, 1992

      6 Eftekhar NS, "Dislocation and instability complicating low friction arthroplasty of the hip joint" 121 : 120-125, 1976

      7 Lewinnek GE, "Dis-locations after total hip-replacement arthroplasties" 60 : 217-220, 1978

      8 Wines AP, "Computed tomography measurement of the accuracy of component version in total hip arthroplasty" 21 : 696-701, 2006

      9 Ha YC, "Ceramic liner fracture after cementless alumina-on-alumina total hip arthroplasty" 458 : 106-110, 2007

      10 Hassan DM, "Accuracy of intraoperative assessment of acetabular prosthesis placement" 13 : 80-84, 1998

      1 D’Lima DD, "The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios" 82 : 315-321, 2000

      2 Kummer FJ, "The effect of acetabular cup orientations on limiting hip rotation" 14 : 509-513, 1999

      3 McLaren RH, "Prosthetic hip angulation" 107 : 705-706, 1973

      4 Carlsson AS, "Postoperative dislocation in the Charnley and Brunswik total hip arthroplasty" 125 : 177-182, 1977

      5 Garcia-Cimbrelo E, "Munuera L. Dislocation in low-friction arthroplasty" 7 : 149-155, 1992

      6 Eftekhar NS, "Dislocation and instability complicating low friction arthroplasty of the hip joint" 121 : 120-125, 1976

      7 Lewinnek GE, "Dis-locations after total hip-replacement arthroplasties" 60 : 217-220, 1978

      8 Wines AP, "Computed tomography measurement of the accuracy of component version in total hip arthroplasty" 21 : 696-701, 2006

      9 Ha YC, "Ceramic liner fracture after cementless alumina-on-alumina total hip arthroplasty" 458 : 106-110, 2007

      10 Hassan DM, "Accuracy of intraoperative assessment of acetabular prosthesis placement" 13 : 80-84, 1998

      11 Cohn BT, "A new technique for the intraoperative determination of acetabular anteversion" 10 : 1565-1566, 1987

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2011-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2009-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2005-01-01 평가 SCI 등재 (등재유지) KCI등재
      2002-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      1999-07-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 1.48 0.37 1.06
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.85 0.75 0.691 0.11
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼