RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재 SCOPUS

      MMC 기반 VSC-HVDC의 사고 위치에 따른 저항형 초전도 한류기와 암 인덕터의 = Analysis of Current Limit and Interruption Characteristics of R-SFCL and Arm Inductor According to Fault Location of MMC based HVDC

      한글로보기

      https://www.riss.kr/link?id=A108948611

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      High voltage direct current (HVDC) has gained prominence as a method for connecting renewable energy sources and interconnecting electric power systems between countries. Recently, the modular multilevel converter (MMC) has been developed and is under...

      High voltage direct current (HVDC) has gained prominence as a method for connecting renewable energy sources and interconnecting electric power systems between countries. Recently, the modular multilevel converter (MMC) has been developed and is undergoing construction worldwide. MMC-HVDC represents a new conversion technology that can address the issues of switching loss and harmonics. During a fault in the MMC-HVDC system, the fault current rises rapidly due to the discharging of the SM capacitor, making it difficult to interrupt with continuous AC side current feed. This phenomenon leads to the destruction of semiconductor devices. To resolve this issue, superconducting fault current limiters with fast response characteristics have been applied to the MMC. The SM capacitor discharge continues until all IGBTs are blocked. Generally, the IGBT block delay is about 3 ms. However, the response time of the Resistive SFCL (R-SFCL) is faster than 3 ms. In this study, the characteristics of R-SFCL and the arm inductor under multiple fault locations in a long cable of the MMC system are confirmed using PSCAD. The R-SFCL is modeled based on actual experimental data. As a result, as the inductor’s capacity increases, the peak current decreases, and the farther the fault location is, the faster the DC current reaches zero-point. Conversely, in the case of R-SFCL, as the resistance increases, the peak current decreases, and the closer the fault location is, the faster the DC current reaches zero-point.

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼