      하악 구치부에서 $Br{\aa}nemark$가 $TiUnite^{(R)}$ implant를 이용한 단일 치아수복의 후향적 연구 = A Retrospective study on $Br{\aa}nemark$ $TiUnite^{(R)}$ implant for mandibular posterior single tooth replacement

      한글로보기

      https://www.riss.kr/link?id=A101528289

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      The purpose of this study was to evaluate 6 years cumulative survival rate (CSR, %) of mandibular posterior single tooth implants replaced with $Br{\aa}nemark$ $TiUnite^{(R)}$ implant system. The findings from this study were as followed ; 1. The 112 ...

      The purpose of this study was to evaluate 6 years cumulative survival rate (CSR, %) of mandibular posterior single tooth implants replaced with $Br{\aa}nemark$ $TiUnite^{(R)}$ implant system. The findings from this study were as followed ; 1. The 112 (111 persons) single implants that were placed in the mandibular posterior region were successful except 4 cases and showed 96.42% CSR. 2. The 55 (55 persons) single implants that were placed in the mandibular first molar region were successful except 2 cases and showed 96.36% survival rate. And, among the 57 (56 persons) single implants replacing the mandibular second molar. 2. failed showing 96.49% survival rate. There was no significant statistical difference. 3. Among the total 112 implants, 5.0mm wide diameter implants were placed in 96 cases(85.7%) showing 96.9% survival rate. 4.0mm standard diameter implants were placed in 16 cases showing 93.8% survival rate. There was no significant statistical difference. 4. Long implants above 10.0mm length were placed 103 cases(91.0%) and showed 96.1% survival rate. Short implants within 8.5mm length were placed 9 cases and showed 100% survival rate. There was no significant statistical difference. 5. 37 implants placed in type I, II bone quality were showed higher survival rate(100%) than that of 52 implants placed in type III, IV bone quality(92.3%). But, there was no significant statistical difference. In conclusion, $Br{\aa}nemark$ $TiUnite^{(R)}$ implant showed successful results when replacing manbibular single molar.

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼