RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재 SCOPUS

      보행 재활 로봇을 위한 2자유도 족관절 기구 개발

      한글로보기

      https://www.riss.kr/link?id=A100521219

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      In this paper, we designed and tested an ankle joint mechanism for a gait rehabilitation robot. Gait rehabilitation programs are designed to improve the natural leg motion of patients who have lost their walking capabilities by accident or disease. St...

      In this paper, we designed and tested an ankle joint mechanism for a gait rehabilitation robot. Gait rehabilitation programs are designed to improve the natural leg motion of patients who have lost their walking capabilities by accident or disease. Strengthening the muscles of the lower-limbs and stimulation of the nervous system corresponding to walking helps patients to walk again using gait assistive devices. It is an obvious requirement that the rehabilitation system’s motion should be similar to and as natural as the normal gait. However, the system being used for gait rehabilitation does not pay much attention to ankle joints, which play an important role in correct walking as the motion of the ankle should reflect the movement of the center of gravity (COG) of the body. Consequently, we have designed an ankle mechanism that ensures the safety of the patient as well as efficient gait training. Also, even patients with low leg muscle strength are able to operate the ankle joint due to the direct-drive mechanism without a reducer. This safety feature prevents any possible adverse load on the human ankle. The additional degree of freedom for the roll motion achieves a gait pattern which is similar to the normal gait and with a greater degree of comfort.

      더보기

      목차 (Table of Contents)

      • Abstract
      • Ⅰ. 서론
      • Ⅱ. 사람의 보행 패턴과 족관절의 관계 분석
      • Ⅲ. 기구 설계
      • Ⅳ. 성능 평가
      • Abstract
      • Ⅰ. 서론
      • Ⅱ. 사람의 보행 패턴과 족관절의 관계 분석
      • Ⅲ. 기구 설계
      • Ⅳ. 성능 평가
      • Ⅴ. 결론
      • REFERENCES
      더보기

      참고문헌 (Reference)

      1 이상룡, "족압패턴에 의한 보행보조기를 위한 입각기 감지기법" 제어·로봇·시스템학회 17 (17): 223-228, 2011

      2 정진엽, "정상 한국인의 3차원 보행 분석 - 예비 보고 -" 대한정형외과학회 40 (40): 83-88, 2005

      3 김현철, "상지 외골격 로봇 제어를 위한 인체 팔 동작의 기구학 및 동역학적 분석 - 파트 2: 제한조건의 선형 결합" 제어·로봇·시스템학회 20 (20): 875-881, 2014

      4 김용국, "발목재활로봇을 위한 6축 힘/모멘트센서 설계" 제어·로봇·시스템학회 19 (19): 357-363, 2013

      5 정경훈, "만성 뇌졸중 환자에서 운동 기능 회복에 대한 로봇-보조 보행치료의 효과" 대한재활의학회 32 (32): 258-266, 2008

      6 G. Morone, "Who may have durable benefit from robotic gait training? A 2-year follow-up randomized controlled trial in patients with subacute stroke" 43 : 1140-1142, 2011

      7 G. Colombo, "Treadmill training of paraplegic patients using a robotic orthosis" 37 (37): 693-700, 2000

      8 G. S. Heo, "The study on sensor system for human gait analysis" Kyounpook National University 2009

      9 I. Schwartz, "The effectiveness of locomotor therapy using robotic-assisted gait training in subacute stroke patients : a randomized controlled trial" 1 (1): 516-523, 2009

      10 D. Gijbels, "The Armeo Spring as training tool to improve upper limb functionality in multiple sclerosis : a pilot study" 8 (8): 2011

      1 이상룡, "족압패턴에 의한 보행보조기를 위한 입각기 감지기법" 제어·로봇·시스템학회 17 (17): 223-228, 2011

      2 정진엽, "정상 한국인의 3차원 보행 분석 - 예비 보고 -" 대한정형외과학회 40 (40): 83-88, 2005

      3 김현철, "상지 외골격 로봇 제어를 위한 인체 팔 동작의 기구학 및 동역학적 분석 - 파트 2: 제한조건의 선형 결합" 제어·로봇·시스템학회 20 (20): 875-881, 2014

      4 김용국, "발목재활로봇을 위한 6축 힘/모멘트센서 설계" 제어·로봇·시스템학회 19 (19): 357-363, 2013

      5 정경훈, "만성 뇌졸중 환자에서 운동 기능 회복에 대한 로봇-보조 보행치료의 효과" 대한재활의학회 32 (32): 258-266, 2008

      6 G. Morone, "Who may have durable benefit from robotic gait training? A 2-year follow-up randomized controlled trial in patients with subacute stroke" 43 : 1140-1142, 2011

      7 G. Colombo, "Treadmill training of paraplegic patients using a robotic orthosis" 37 (37): 693-700, 2000

      8 G. S. Heo, "The study on sensor system for human gait analysis" Kyounpook National University 2009

      9 I. Schwartz, "The effectiveness of locomotor therapy using robotic-assisted gait training in subacute stroke patients : a randomized controlled trial" 1 (1): 516-523, 2009

      10 D. Gijbels, "The Armeo Spring as training tool to improve upper limb functionality in multiple sclerosis : a pilot study" 8 (8): 2011

      11 C. Breazeal, "Socially intelligent robots" 12 (12): 19-22, 2005

      12 K. C. Kong, "Smooth and continuous human gait phase detection based on foot pressure patterns" 3678-3683, 2008

      13 R. A. Mann, "Running symposium" 1 (1): 190-224, 1981

      14 E. Rocon, "Rehabilitation robotics: a wearable exo-skeleton for tremor assessment and suppression" 2271-2276, 2005

      15 G. R. West, "Powered gait orthosis and method of utilizing same"

      16 H. Kawamoto, "Power assist method based on phase sequence driven by interaction between human and robot Suit" 491-496, 2004

      17 I. Diaz, "Lower-limb robotic rehabilitation: literature review and challenges" 2011 : 11-, 2011

      18 A. J. Del-Ama, "Hybrid gait train-ing with an overground robot for people with incomplete spinal cord injury : a pilot study" 8 (8): 2014

      19 J. Rose, "Human Walking" Williams & Wilkins 26-, 1994

      20 S. Freivogel, "Gait training with the newly developed"LokoHelp"-system is feasible for non-ambulatory patients after stroke, spinal cord and brain injury. A feasibility study" 22 (22): 625-632, 2008

      21 J. Mehrholz, "Electromechanical and robot-assisted arm training for improving generic activities of daily living, arm function, and arm muscle strength after stroke" CD006876-, 2012

      22 K. Cerny, "Effect of an unrestricted knee-ankle-foot orthosis on the stance phase of gait in healthy persons" 13 (13): 1121-1127, 1990

      23 A. Picelli, "Does robotic gait training improve balance in Parkinson's disease? A randomized controlled trial" 18 (18): 990-993, 2012

      24 J. L. Herder, "Development of a statically balanced arm support: ARMON" 281-286, 2005

      25 K. Kiguchi, "Development of a 3DOF mobile exoskeleton robot for human upper-limb motion assist" 56 (56): 678-691, 2008

      26 J. F. Veneman, "Design and evaluation of the Lopes exoskeleton robot for interactive gait rehabilitation" 15 (15): 379-386, 2007

      27 S. K. Banala, "Active leg exoskeleton (ALEX) for gait rehabilitation of motor-impaired patients" 401-407, 2007

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2011-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2009-12-29 학회명변경 한글명 : 제어ㆍ로봇ㆍ시스템학회 -> 제어·로봇·시스템학회 KCI등재
      2009-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2008-01-02 학술지명변경 한글명 : 제어.자동화.시스템공학 논문지 -> 제어.로봇.시스템학회 논문지
      외국어명 : Journal of Control, Automation and Systems Engineering -> Journal of Institute of Control, Robotics and Systems
      KCI등재
      2007-10-29 학회명변경 한글명 : 제어ㆍ자동화ㆍ시스템공학회 -> 제어ㆍ로봇ㆍ시스템학회
      영문명 : The Institute Of Control, Automation, And Systems Engineers, Korea -> Institute of Control, Robotics and Systems
      KCI등재
      2007-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2005-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2002-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      1999-07-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.69 0.69 0.55
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.45 0.39 0.509 0.14
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼