To meet the increasing demand with the limited resource, every country is trying all-out to find a solution. A large part of energy demand is used in the building, so a Korean Energy Saving Design Standard which is right to the country conditions is i...
To meet the increasing demand with the limited resource, every country is trying all-out to find a solution. A large part of energy demand is used in the building, so a Korean Energy Saving Design Standard which is right to the country conditions is immediately needed. This study is trying to analyze the sensitivity of architectural elements through a simulation which considered architecture, electricity, machine overall with the typical thermal load analysis program Transys and to present a quantitative data to set up an adequate Energy Saving Design. The results of this study are as follows. Sensitivity analysis show that setting windows are more sensitive than other factors which we adopt at cooling loa. and setting temperature are more sensitive than other factors which we adopt at heating load.