      PURPOSE. The aim of this study was to evaluate the effect of cyclic loading and screw retightening on reverse torque value (RTV) in external and internal type implants. MATERIALS AND METHODS. Cement-retained abutments were connected with 30 Ncm torque...

      PURPOSE. The aim of this study was to evaluate the effect of cyclic loading and screw retightening on reverse torque value (RTV) in external and internal type implants. MATERIALS AND METHODS. Cement-retained abutments were connected with 30 Ncm torque to external and internal type implants. Experimental groups were classified according to implant connection type and retightening/loading protocol. In groups with no retightening, RTV was evaluated after cyclic loading for 100,000 cycles. In groups with retightening, RTV was measured after 3, 10, 100 cycles as well as every 20,000 cycles until 100,000 cycles of loading. RESULTS. Every group showed decreased RTV after cyclic loading. Before and after cyclic loading, external type implants had significantly higher RTVs than internal type implants. In external type implants, retightening did not affect the decrease in RTV. In contrast, retightening 5 times and retightening after 10 cycles of dynamic loading was effective for maintaining RTV in internal type implants. CONCLUSION. Retightening of screws is more effective in internal type implants than external type implants. Retightening of screws is recommended in the early stage of functional loading.

      더보기

      참고문헌 (Reference)

      1 김진만, "수종 임플랜트 지대주나사의 반복하중 후나사풀림에 관한 연구" 대한치과보철학회 41 (41): 519-531, 2003

      2 Kim KS, "Variation in the total lengths of abutment/implant assemblies generated with a function of applied tightening torque in external and internal implant-abutment connection" 22 : 834-839, 2011

      3 Cardoso M, "Torque removal evaluation of prosthetic screws after tightening and loosening cycles: an in vitro study" 23 : 475-480, 2012

      4 Tzenakis GK, "The effect of repeated torque and salivary contamination on the preload of slotted gold implant prosthetic screws" 88 : 183-191, 2002

      5 Binon PP, "The effect of eliminating implant/abutment rotational misfit on screw joint stability" 9 : 511-519, 1996

      6 Jung RE, "Systematic review of the survival rate and the incidence of biological, technical, and aesthetic complications of single crowns on implants reported in longitudinal studies with a mean follow-up of 5 years" 23 : 2-21, 2012

      7 Andersson B, "Single-tooth restorations supported by osseointegrated implants: results and experiences from a prospective study after 2 to 3 years" 10 : 702-711, 1995

      8 Siamos G, "Relationship between implant preload and screw loosening on implant-supported prostheses" 28 : 67-73, 2002

      9 Cavazos E, "Preventing loosening of implant abutment screws" 75 : 566-569, 1996

      10 Henry PJ, "Osseointegrated implants for singletooth replacement: a prospective 5-year multicenter study" 11 : 450-455, 1996

      1 김진만, "수종 임플랜트 지대주나사의 반복하중 후나사풀림에 관한 연구" 대한치과보철학회 41 (41): 519-531, 2003

      2 Kim KS, "Variation in the total lengths of abutment/implant assemblies generated with a function of applied tightening torque in external and internal implant-abutment connection" 22 : 834-839, 2011

      3 Cardoso M, "Torque removal evaluation of prosthetic screws after tightening and loosening cycles: an in vitro study" 23 : 475-480, 2012

      4 Tzenakis GK, "The effect of repeated torque and salivary contamination on the preload of slotted gold implant prosthetic screws" 88 : 183-191, 2002

      5 Binon PP, "The effect of eliminating implant/abutment rotational misfit on screw joint stability" 9 : 511-519, 1996

      6 Jung RE, "Systematic review of the survival rate and the incidence of biological, technical, and aesthetic complications of single crowns on implants reported in longitudinal studies with a mean follow-up of 5 years" 23 : 2-21, 2012

      7 Andersson B, "Single-tooth restorations supported by osseointegrated implants: results and experiences from a prospective study after 2 to 3 years" 10 : 702-711, 1995

      8 Siamos G, "Relationship between implant preload and screw loosening on implant-supported prostheses" 28 : 67-73, 2002

      9 Cavazos E, "Preventing loosening of implant abutment screws" 75 : 566-569, 1996

      10 Henry PJ, "Osseointegrated implants for singletooth replacement: a prospective 5-year multicenter study" 11 : 450-455, 1996

      11 Jemt T, "Osseointegrated implants for single tooth replacement: a 1-year report from a multicenter prospective study" 6 : 29-36, 1991

      12 Schwarz MS, "Mechanical complications of dental implants" 11 : 156-158, 2000

      13 Tsuge T, "Influence of lateral-oblique cyclic loading on abutment screw loosening of internal and external hexagon implants" 28 : 373-381, 2009

      14 Maeda Y, "In vitro differences of stress concentrations for internal and external hex implant-abutment connections: a short communication" 33 : 75-78, 2006

      15 Binon PP, "Implants and components: entering the new millennium" 15 : 76-94, 2000

      16 McGlumphy EA, "Implant screw mechanics" 42 : 71-89, 1998

      17 Delben JA, "Evaluation of the effect of retightening and mechanical cycling on preload maintenance of retention screws" 26 : 251-256, 2011

      18 Haack JE, "Elongation and preload stress in dental implant abutment screws" 10 : 529-536, 1995

      19 Park JK, "Effects of abutment screw coating on implant preload" 19 : 458-464, 2010

      20 Ricciardi Coppedê A, "Effect of repeated torque/mechanical loading cycles on two different abutment types in implants with internal tapered connections: an in vitro study" 20 : 624-632, 2009

      21 Guzaitis KL, "Effect of repeated screw joint closing and opening cycles on implant prosthetic screw reverse torque and implant and screw thread morphology" 106 : 159-169, 2011

      22 Weiss EI, "Effect of repeated closures on opening torque values in seven abutment-implant systems" 84 : 194-199, 2000

      23 Lee JH, "Axial displacements in external and internal implant-abutment connection" 25 : e83-e89, 2014

      24 Bickford JH, "An introduction to the design and behavior of bolted joints" Marcel Dekker Inc 1995

      25 Theoharidou A, "Abutment screw loosening in single-implant restorations: a systematic review" 23 : 681-690, 2008

      26 Khraisat A, "Abutment screw loosening and bending resistance of external hexagon implant system after lateral cyclic loading" 6 : 157-164, 2004

      27 Pjetursson BE, "A systematic review of the survival and complication rates of implant-supported fixed dental prostheses (FDPs) after a mean observation period of at least 5 years" 23 : 22-38, 2012

      28 Artzi Z, "A screw lock for single-tooth implant superstructures" 130 : 677-682, 1999

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2010-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2009-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2009-01-01 평가 학술지 분리 (기타) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.91 0.23 0.75
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.67 0.59 0.57 0.04
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼