RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재 SCIE SCOPUS

      성견에서 즉시 임플란트 식립시 국내 임플란트에서의 골 유착반응에 관한 연구 = Study on Osseointegration of the Immediate Placement Using Korean Implant Systems in Beagle Dog

      한글로보기

      https://www.riss.kr/link?id=A101528322

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      This study was attempted to evaluate home-manufactured implants by placing $Stage-1^{(R)}$ Implant (Lifecore, Co., USA) whose surface is treated with REM that has already been varified clinically,$Chaorum^{(R)}$ Implant(Chaorum Co., Korea) whose surfa...

      This study was attempted to evaluate home-manufactured implants by placing $Stage-1^{(R)}$ Implant (Lifecore, Co., USA) whose surface is treated with REM that has already been varified clinically,$Chaorum^{(R)}$ Implant(Chaorum Co., Korea) whose surface treatment is same as that of Stage-1 Implant and $Atlas^{(R)}$ Implant(Cewellmedi Co., Korea) whose surface is treated with anodic oxidation immediately after the teeth of experimental animals were extracted to compare histological findings among them. Stage-l Implant(diameter: 3.5mm, length: IOmm), Chaorum Implant(diameter: 3.3mm, length: 8.5mm) and Cowell medi Implant(diameter: 4.0mm, length: 8.0mm) were placed into the mandible premolars of 2 adult beagle dogs immediately after their teeth were extracted, and then histological findings were analyzed at 6 weeks. After those implants were inserted directly after their teeth were extracted, the results of periotest were recorded, radiography was done, the subjects went through thorough control for 6 weeks, and then comparison among periotest, radiography and histological finding was made. After comparison of those findings, the values of periotest were satisfactory and bone healing was relatively satisfactory on radiography at 6 weeks. For osseointegration with the bone tissue, Stage-1 was 45.3%, Chaorum 55.3%, and Cowellmedi 52.5%, which was a satisfactory result. Although implant surgery immediately after teeth were extracted involves difficulties among recent implant surgeries, it is being frequently used in that it may reduce surgery hours, the frequency of surgery, and bone loss for patients. This experiment was conducted to evaluate the technological levels of home-manufactured implants that have been remarkably developed in recent years and in conclusion, those implants showed nearly similar result.

      더보기

      참고문헌 (Reference)

      1 "interface mechanics and histology of titanium and hydroxyapatite-coated titanium for dental implant applications" 15-22, intjoralmaxillofacimplants1987

      2 "Three-year retrospective evaluation of 50 consecutive cases" 1993

      3 "The use of reduced healing times on ITI implants with a sandblasted and acid- etched (SLA) surface : early results from clinical trials on ITI SLA implants" 28 : 2-8, 2002

      4 "The longitudinal clinical effectiveness of osseointegrated dental implants" 451-457, 1990

      5 "The applicability of osseointegrated implants in the treatmentof partially edentulous patients Three ye ars result of a prospectivemulticenter study" 123-129, 1993

      6 "The Effect of Hydroxyapatite coating on bone Growth into porous titanium alloy implants" 71 213-216, 1989

      7 "Reconstruction of severely resorbed edentulous maxillae using osseointegrated fixturesin immediate autogenous bone grafts" nemark 233-246, 1990

      8 "Osseous adaptation to continuous loading of rigid endosseous implant" 95-111, amjorthod1984

      9 "Osseointegration in clinical dentistry" Branemark Quintessence Publishing Co inc 1985

      10 "Osseointegrated implants in the treatment of the edentulous jaw Experience from a 10-years period" Branemark 1-132, 1977

      1 "interface mechanics and histology of titanium and hydroxyapatite-coated titanium for dental implant applications" 15-22, intjoralmaxillofacimplants1987

      2 "Three-year retrospective evaluation of 50 consecutive cases" 1993

      3 "The use of reduced healing times on ITI implants with a sandblasted and acid- etched (SLA) surface : early results from clinical trials on ITI SLA implants" 28 : 2-8, 2002

      4 "The longitudinal clinical effectiveness of osseointegrated dental implants" 451-457, 1990

      5 "The applicability of osseointegrated implants in the treatmentof partially edentulous patients Three ye ars result of a prospectivemulticenter study" 123-129, 1993

      6 "The Effect of Hydroxyapatite coating on bone Growth into porous titanium alloy implants" 71 213-216, 1989

      7 "Reconstruction of severely resorbed edentulous maxillae using osseointegrated fixturesin immediate autogenous bone grafts" nemark 233-246, 1990

      8 "Osseous adaptation to continuous loading of rigid endosseous implant" 95-111, amjorthod1984

      9 "Osseointegration in clinical dentistry" Branemark Quintessence Publishing Co inc 1985

      10 "Osseointegrated implants in the treatment of the edentulous jaw Experience from a 10-years period" Branemark 1-132, 1977

      11 "Optimization of surface micromorphology for enhanced osteoblastresponses in vitro" 302-310, intjoralmaxillofacimplants1992

      12 "Optimal implant stabilization in low density bone" 12 : 423-432, 2001

      13 "Mandibular bone response to plasma-sprayed coatings of hydroxyapatite Int Prosthodont" 53-58, 1990

      14 "Kineticsof bone growth into cylindrical channels in aluminum oxide and titanium" 375-400, 1972

      15 "Integration of screw implants in the rabbit a 1-year follow-up of removal torque of titanium implants" 69-75, 1987

      16 "Influence of surface characteritics on bone integration of titanium implants A histomorphometric study in miniature pigs" Steinemann S 889-902,

      17 "Influence of surface characteritics on bone integration of titanium implants A histomorphometric study in miniature pigs" Steinemann S 889-902,

      18 "Influence of surface characteristics on bone integration of titaniumimplants A histomorphometric study in miniature pigs" Steinemann S 889-902,

      19 "Immediate implantation of pure titanium implants into extraction sockets of Macaca facicularis. Part Ⅱ : Histologic observations" 11 : 489-, 1996

      20 "Histomorphometric study of unthreaded hydroxyapatite coated and titanium coated implants in rabbit bone" 485-490, 1992

      21 "Histomorphometric studies of hydroxyapatite coated and uncoated CP titanium threaded implants in bone" 399-404, 1991

      22 "Experimental study of bone response to a new surface treatment of endosseous titanium implants" 10 : 126-131, 2001

      23 "Experimental study of bone response to a new surface treatment of endosseous titanium implants" 10 : 126-131, 2001

      24 "Evaluation of hydroxyapatite-coated titanium dental implants in dogs" 601-607, joralmaxillofacsurg1987

      25 "Effect of titaium surface roughness on proliferation, differentitaion, and protein synthesis of human osteoblast-like cell(MG63)" 29 : 389-401, 1995

      26 "Direct bone anchorage of oral implants Clinical and experimental considerations of the concept of osseointegration" 30-41, intjprosthodont1990

      27 "Characteerization of titanium implant surface 3" 45-158, 1988

      28 "Bone response to machined and resorbable blast material titaniumimplants: An experimental study in rabbits" 28 : 2-8, 2002

      29 "Bone response to machined and resorbable blast material titaniumimplants: An experimental study in rabbits" 28 : 2-8, 2002

      30 "Bone response to machined and resorbable blast material titanium implants: An experimental study in rabbits" 28 : 2-8, 2002

      31 "Bone implant contact and bone quality: Evaluation of expected and actual bone contact on machined and osseotite implant surface" 22 : 535-545, 2002

      32 "Attachment of bone to threaded implants by ingrowth and mechanical interlocking" 401-412,

      33 "An evaluationof variables influencing implant fixation by direct bone apposition" 875-901, 1985

      34 "A clinical evaluation of fixed bridge restorations supported by the combination of tooth and osseointegrated tianinum implant" Branemark 307-312, 1986

      35 "A 15-year study of osseointegrated implants in the treatment of edentulous jaw" and Branemark 387-416, 1981

      36 "A 1-year follow-up of implants of differing surface roughnessplaced in rabbit bone" 12 : 486-494, 1997

      37 "A 1-year follow-up of implants of differing surface roughness placed in rabbit bone" 12 : 486-494, 1997

      더보기

      동일학술지(권/호) 다른 논문

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2012-03-21 학술지명변경 한글명 : The Journal of the Korean Academy of Periodontology (JPIS) -> Journal of Periodontal & Implant Science
      외국어명 : THE JOURNAL OF KOREAN ACADEMY OF PERIODONTOLOGY -> Journal of Periodontal & Implant Science
      KCI등재
      2011-03-22 학술지명변경 한글명 : 대한치주과학회지 -> The Journal of the Korean Academy of Periodontology (JPIS) KCI등재
      2010-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2008-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2005-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2004-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2002-07-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.91 0.14 0.66
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.56 0.45 0.49 0.02
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼