RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재 SCI SCIE SCOPUS

      Measurement of the Electric Properties of the KSTAR CS Model Coil

      한글로보기

      https://www.riss.kr/link?id=A104336223

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      The maximum current, the self inductance and the lap joint resistance of a split-pair superconducting pulse magnet were experimentally inspected. The pulse magnet mainly consists of two KSTAR central solenoid (CS) model coils, which are wound, continu...

      The maximum current, the self inductance and the lap joint resistance of a split-pair superconducting pulse magnet were experimentally inspected. The pulse magnet mainly consists of two KSTAR central solenoid (CS) model coils, which are wound, continuous Nb₃Sn cable-in-conduit conductors (CICC) with Incoloy 908 jackets. The pulse magnet initially could not achieve its rated current over several days whereas the temperature of the magnet surfaces and coolant outlets stayed at 5 ~ 8 K. A training effect and a ramp rate limitation were suspected of being the cause at the beginning. However the magnet's supporting structure was found to have been exceedingly warm in that period, and the maximum current clearly corresponded to the temperature of the supporting structure. The self inductance of the pulse magnet was measured with an LCR meter at 0.1 ~ 1 kHz at room temperature, but the inductance was nearly double the design value. The self inductance was also measured by means of a decay time constant method at 5 K and, at values of current above 200 A, was found to be originally the same as the design value, however, it dynamically increased below that current. Supplemental calculation showed that the permeability of Incoloy 908 could have a detrimental impact upon the dynamic variation of the self inductance. The lap joint resistance was successfully obtained by measuring the voltage drops between two CICCs at 5 K. Another trial measuring the voltage drops between the two outer surfaces of the lap joint resulted in a nonphysical result that violated Ohm's law.

      더보기

      참고문헌 (Reference)

      1 S. Lee, 12 : 583-, 2002

      2 Y. Chu, 2007

      3 Y. M. Park, 2006

      4 L. S. Toma, "MIT report" MIT 1994

      5 J. Schultz, "MIT Report" 1995

      6 J. Leuer, "GA Report" 2007

      1 S. Lee, 12 : 583-, 2002

      2 Y. Chu, 2007

      3 Y. M. Park, 2006

      4 L. S. Toma, "MIT report" MIT 1994

      5 J. Schultz, "MIT Report" 1995

      6 J. Leuer, "GA Report" 2007

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2011-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2009-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2007-01-01 평가 SCI 등재 (등재유지) KCI등재
      2005-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2002-07-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2000-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.47 0.15 0.31
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.26 0.2 0.26 0.03
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼