RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재후보

      혈관내 초음파 영상에 의한 형태 및 조직병리 소견 평가 = Geometric Accuracy and Histopathologic Validation of Intravascular Ultrasound Imaging

      한글로보기

      https://www.riss.kr/link?id=A3306641

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      N/A

      N/A

      더보기

      다국어 초록 (Multilingual Abstract)

      Background: To evaluate geometric accuracy of intravascular ultrasound and histopathologic validation of ultrasound and angioscopy we studied postmortem human arterial segments and phantoms in vitro. Method: We used 7 to 9 French fiberoptic angioscope...

      Background: To evaluate geometric accuracy of intravascular ultrasound and histopathologic validation of ultrasound and angioscopy we studied postmortem human arterial segments and phantoms in vitro. Method: We used 7 to 9 French fiberoptic angioscopes and 30 MHz intravascular ultrasound imaging catheter. We assessed the area and wall thickness on 9 phantom vessels and 12 arteries with different imaging media and 30 angle of incidence. To evaluate histopathologic validation of ultrasound and angioscopy, the images of 12 normal and 55 abnormal (stable atheroma, disrupted atheroma and thrombi) vessels were compared with histology. Results: Geometric accuracy: The measured area were smaller in blood (7.2-7.6%) and gel (10,8-13.6%) than that of saline. A 30 angle of incidence resulted in 14.2%-16.3% increase in lumen area and 10,6% increase in wall thickness. Ultrasonic wall thickness of human vessels correlated closely with the actual measured thickness (r=0,93). Histopatholgic validation: the sensitivity specifictiy and accuracy of both method were greater than 96% in normal vessel and 90% in stable atheroma. For normal vessel predictive value was better for angioscopy than for ultrasound. For stable atheroma the predictive value were 77%. for angioscopy and 78% for ultrasound due to classification of disrupted atheroma to stable atheroma. For thrombus detection sensitivity was 62% for ultra- sound due to false negative interpretation of lamina clots and atheroma in vessel. Conclusion: With ultrasound measurement, lumen area and wall thickness were accurate when the catheter placement was coaxial. For histopathologic validation, angioscopy and ultrasound images had significant agreement with the results obtained from histology.

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼