      KCI등재 SCI SCIE SCOPUS

      Characteristic Evaluation of a Novel CdTe Photon Counting Detector for X-Ray Imaging

      한글로보기

      https://www.riss.kr/link?id=A104107748

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      The purpose of this paper is to investigate the characteristics of a novel cadmium-telluride (CdTe)photon counting detector optimized for X-ray imaging applications. CdTe was studied as a potential detector material for hard X-ray and gamma-ray detect...

      The purpose of this paper is to investigate the characteristics of a novel cadmium-telluride (CdTe)photon counting detector optimized for X-ray imaging applications. CdTe was studied as a potential detector material for hard X-ray and gamma-ray detection. In this study, we used a CdTe photon counting detector manufactured by AJAT Ltd. (PID 350, Finland) for the purposes of both Xray and gamma-ray detection. However, it is noted that X-ray detection can be limited by the characteristics of gamma-ray detectors. For the investigation of the characteristics of a detector for X-ray imaging, the detector has been studied in terms of detector calibration, count rate, and pixel sensitivity variation by using a poly-energetic X-ray. The detector calibration was evaluated to determine the effects of offset, gain, and energy. An optimal calibration increases the accuracy of the output energy spectrum. The pixel sensitivity variation was evaluated using profiles of various rows and columns from white (with X-ray) and dark (without X-ray) images. The specific trend of each image was observed around the edges of the hybrids. These pixel variations of the CdTe sensor were corrected. The image quality was improved by using the optimal correction method based on an understanding of the pixel sensitivity variation. The maximum recorded count rate of the detector was measured in all pixels. The count rate was measured by setting the energy windows from just above the noise level to the maximum energy. The average count rate was fairly linear up to 1.6 × 106 cps/8 modules and saturated at about 2.2 × 106 cps/8 modules. In this paper, we present several characteristics of the detector and demonstrate the improved spectrum and image obtained after calibration and correction. These results show that the novel CdTe photon counting detector can be used in conventional X-ray imaging, but exhibits limitations when applied to spectral X-ray imaging.

      더보기

      참고문헌 (Reference)

      1 K. Spartiotis, 550 : 267-, 2005

      2 R. Ballabriga, 6 : 01052-, 2011

      3 T. Takahashi, 48 : 4-, 2001

      4 R. Aamir, 6 : 01059-, 2011

      5 L. J. Meng, 604 : 548-, 2009

      6 K. Spartiotis, 4775237 : 518-, 2008

      7 W. C. Barber, 7258 : 725824-725821, 2009

      8 Y. M. Chiang, 12 : 3-, 1997

      9 K. Taguchi, 38 : 2-, 2011

      10 G. F. Knoll, "Radiation Detection and Measurements" John Wiley and Sons, Inc. 2010

      1 K. Spartiotis, 550 : 267-, 2005

      2 R. Ballabriga, 6 : 01052-, 2011

      3 T. Takahashi, 48 : 4-, 2001

      4 R. Aamir, 6 : 01059-, 2011

      5 L. J. Meng, 604 : 548-, 2009

      6 K. Spartiotis, 4775237 : 518-, 2008

      7 W. C. Barber, 7258 : 725824-725821, 2009

      8 Y. M. Chiang, 12 : 3-, 1997

      9 K. Taguchi, 38 : 2-, 2011

      10 G. F. Knoll, "Radiation Detection and Measurements" John Wiley and Sons, Inc. 2010

      11 J. Prekeges, "Nuclear Medicine Instrumentation" Jones & Bartlett Learning 2009

      더보기

      동일학술지(권/호) 다른 논문

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2011-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2009-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2007-01-01 평가 SCI 등재 (등재유지) KCI등재
      2005-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2002-07-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2000-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.47 0.15 0.31
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.26 0.2 0.26 0.03
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼