RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재 SCOPUS

      전안부 빛간섭단층촬영을 이용한 백내장 수술 후 앞방깊이와 앞방각의 변화 측정 = Changes of Anterior Chamber Depth and Angle After Cataract Surgery Measured by Anterior Segment OCT

      한글로보기

      https://www.riss.kr/link?id=A100523491

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Purpose: To report the change of anterior chamber parameters according to cataract severity after cataract surgery and to determine its relationship to the severity of cataract by using anterior segment optical coherence tomography. Methods: We measur...

      Purpose: To report the change of anterior chamber parameters according to cataract severity after cataract surgery and to determine its relationship to the severity of cataract by using anterior segment optical coherence tomography. Methods: We measured the anterior chamber parameters in 19 eyes of 14 patients before, 1 week after, and 1 month after cataract surgery by slit lamp-adapted optical coherence tomography (SL-OCT). The measured parameters were as follows : the anterior chamber depth (ACD), the angle-opening distance 250 μm from the scleral spur (AOD250), the angle-opening distance 500 μm from the scleral spur (AOD500), and the trabecular-iris angle (TIA). We analyzed the relationship between the severity of cataract and the change of the anterior chamber parameters. Results: The ACD, AOD250, AOD500, and TIA increased significantly at postoperative 1 week (P=0.000, 0.002, 0.005, 0.022) and 1 month (P=0.000, 0.004, 0.001, 0.002). The preoperative parameters were negatively correlated with the differences between the postoperative 1 week and preoperative parameters (γ=-0.834, -0.591, -0.421, -0.826) and between postoperative 1 month and preoperative parameters (γ=-0.659, -0.700, -0.770, -0.821). The change of parameters at postoperative 1 week (by N P=0.959, 0.916, 0.824, 1.000, by C P=0.454, 0.665, 0.578, 0.578) and 1 month (by N P=0.858, 0.973, 0.959, 0.959, by C P=0.999, 0.207, 0.950, 0.981) were not significantly different according to the severity of cataract (N, C). Conclusions: Our results showed that cataract surgery significantly deepened the anterior chamber and widened its angle. The shallower and narrower the preoperative anterior chamber depth and angle were, respectively, the greater the postoperative changes of anterior chamber depth and angle were. J Korean Ophthalmol Soc 2008;49(9):1443-1452

      더보기

      참고문헌 (Reference)

      1 Pavlin CJ, "Ultrasound biomicroscopy of anterior segment structures in normal and glaucomatous eyes" 113 : 381-389, 1992

      2 Pereira FA, "Ultrasound biomicroscopic study of anterior segment changes after phacoemulsification and foldable intraocular lens implantation" 110 : 1799-1806, 2003

      3 Lee JH, "The effects of pilocarpine on the anterior chamber depth and angle" 35 : 572-579, 1994

      4 Koo BS, "The effect of extracapsular cataract extraction in patients with chronic angle-closure glaucoma combined with cataract" 37 : 1045-1053, 1996

      5 Yoshida S, "Significance of angle of intraocular lens haptics on anterior chamber depth" 43 : 173-176, 1989

      6 Shibata T, "Quantitative chamber angle measurement utilizing image-processing techniques" 22 : 81-84, 1990

      7 Radhakrishnan S, "Optical coherence tomography imaging of anterior chamber angle" 18 : 375-381, 2005

      8 Memarzadeh F, "Optical coherence tomography assessment of angle anatomy changes after cataract surgery" 144 : 464-465, 2007

      9 Huang D, "Optical coherence tomography" 254 : 1178-1181, 1991

      10 Murphy GE, "Long-term gonioscopy follow-up of eyes with posterior lens implants and no iridectomy" 17 : 227-228, 1986

      1 Pavlin CJ, "Ultrasound biomicroscopy of anterior segment structures in normal and glaucomatous eyes" 113 : 381-389, 1992

      2 Pereira FA, "Ultrasound biomicroscopic study of anterior segment changes after phacoemulsification and foldable intraocular lens implantation" 110 : 1799-1806, 2003

      3 Lee JH, "The effects of pilocarpine on the anterior chamber depth and angle" 35 : 572-579, 1994

      4 Koo BS, "The effect of extracapsular cataract extraction in patients with chronic angle-closure glaucoma combined with cataract" 37 : 1045-1053, 1996

      5 Yoshida S, "Significance of angle of intraocular lens haptics on anterior chamber depth" 43 : 173-176, 1989

      6 Shibata T, "Quantitative chamber angle measurement utilizing image-processing techniques" 22 : 81-84, 1990

      7 Radhakrishnan S, "Optical coherence tomography imaging of anterior chamber angle" 18 : 375-381, 2005

      8 Memarzadeh F, "Optical coherence tomography assessment of angle anatomy changes after cataract surgery" 144 : 464-465, 2007

      9 Huang D, "Optical coherence tomography" 254 : 1178-1181, 1991

      10 Murphy GE, "Long-term gonioscopy follow-up of eyes with posterior lens implants and no iridectomy" 17 : 227-228, 1986

      11 Steuhl KP, "Intraocular pressure and anterior chamber depth before and after extracapsular cataract extraction with posterior chamber lens implantation" 23 : 233-237, 1992

      12 Wirbelauer C, "Imaging of the anterior eye chamber with optical coherence tomography" 222 : 856-862, 2005

      13 Radhakrishnan S, "Comparison of optical coherence tomography and ultrasound biomicroscopy for detection of narrow anterior chamber angles" 123 : 1053-1059, 2005

      14 Lee HJ, "Changes of preoperative and postoperative anterior chamber angle in phacoemulsification and planned extracapsular cataract extraction" 39 : 1170-1175, 1998

      15 Kurimoto Y, "Changes in the anterior chamber configuration after small-incision cataract surgery with posterior chamber intraocular lens implantation" 124 : 775-780, 1997

      16 Shibata T, "Biometry of the lens with respect to age and cataract morphology. Evaluation of Scheimpflug photos of the anterior segment" 185 : 35-42, 1984

      17 Arai M, "Anterior chamber depth after posterior chamber intraocular lens implantation" 72 : 694-697, 1994

      18 Müler M, "Anterior chamber angle measurement with optical coherence tomography: Intraobserver and interobserver variability" 32 : 1803-1808, 2006

      19 Nonaka A, "Angle widening and alteration of ciliary process configuration after cataract surgery for primary angle closure" 113 : 437-441, 2006

      20 Richard DW, "A method for improved biometry of the anterior chamber with a Scheimpflug technique" 29 : 1826-1835, 1988

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2017-01-01 평가 등재학술지 유지 (계속평가) KCI등재
      2013-01-01 평가 등재 1차 FAIL (등재유지) KCI등재
      2010-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2007-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2006-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2005-01-01 평가 등재후보학술지 유지 (등재후보1차) KCI등재후보
      2003-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.22 0.22 0.22
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.23 0.23 0.366 0.02
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼