RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재

      Reduction of Outdoor and Indoor Ambient Dose Equivalent after Decontamination in the Fukushima Evacuation Zones

      한글로보기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Background: One of the most urgent issues following the accident at the Fukushima Daiichi nuclear power plant (FDNPP) was the remediation of the land, in particular, for residential area contaminated by the radioactive materials discharged. In this st...

      Background: One of the most urgent issues following the accident at the Fukushima Daiichi nuclear power plant (FDNPP) was the remediation of the land, in particular, for residential area contaminated by the radioactive materials discharged. In this study, the effect of decontamination on reduction of ambient dose equivalent outdoors and indoors was evaluated. The latter is essential for residents as most individuals spend a large portion of their time indoors. Materials and Methods: From December 2012 to November 2014, thirty-seven Japanese single-family detached wooden houses were investigated before and after decontamination in evacuation zones. Outdoor and indoor dose measurements (n = 84 and 114, respectively) were collected based on in situ measurements using the NaI (Tl) scintillation surveymeter. Results and Discussion: The outdoor ambient dose equivalents [$H^*(10)_{out}$] ranged from 0.61 to $3.71{\mu}Sv\;h^{-1}$ and from 0.23 to $1.32{\mu}Sv\;h^{-1}$ before and after decontamination, respectively. The indoor ambient dose equivalents [$H^*(10)_{in}$] ranged from 0.29 to $2.53{\mu}Sv\;h^{-1}$ and from 0.16 to $1.22{\mu}Sv\;h^{-1}$ before and after decontamination, respectively. The values of reduction efficiency (RE), defined as the ratio by which the radiation dose has been reduced via decontamination, were evaluated as $0.47{\pm}0.13$, $0.51{\pm}0.13$, and $0.58{\pm}0.08$ ($average{\pm}{\sigma}$) when $H^*(10)_{out}$ < $1.0{\mu}Sv\;h^{-1}$, $1.0{\mu}Sv\;h^{-1}$ < $H^*(10)_{out}$ < $2.0{\mu}Sv\;h^{-1}$, and $2.0{\mu}Sv\;h^{-1}$ < $H^*(10)_{out}$, respectively, indicating the values of RE increased as $H^*(10)_{out}$ increased. It was found that the values of RE were $0.53{\pm}0.12$ outdoors and $0.41{\pm}0.09$ indoors, respectively, indicating RE was larger outdoors than indoors. Conclusion: Indoor dose is essential as most individuals spend a large portion of their time indoors. The difference between outdoors and indoors should be considered carefully in order to estimate residents' exposure dose before their returning home.

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼