어린이집에서 이산화탄소와 미세먼지의 장기간 시간적인 변이를 활용한 실내환경수준 평가
김윤지(Yoonjee Kim),이세원(Sewon Lee),반현경(Hyunkyung Ban),차상민(Sangmin Cha),김근배(Geunbae Kim),이기영(Kiyoung Lee) 한국환경보건학회 2017 한국환경보건학회지 Vol.43 No.4
Objectives: The purposes of the study were to analyze the temporal variation of carbon dioxide (CO 2 ) and particulate matter (PM) in daycare centers and evaluate the appropriateness of the official test method of onetime measurement. Methods: Indoor air quality in 46 daycare centers in the Seoul Metropolitan Area was measured as specified in the official test method of Indoor Air Quality Management law. In addition, indoor air quality in the 46 daycare centers was measured over 37 days using a real-time monitor (AirGuard K). Results: The daily means of CO 2 and PM in the 46 daycare centers were 1042.74 ± 134.45 ppm and 67.60 ± 18.25 µg/m 3 , respectively. Indoor air quality in the daycare centers showed significant temporal fluctuation. Measurements for single days were significantly different from the 37-day average exposure. Relative error of short term exposure decreased with an increase in the number of sampling days. The noncompliance rate for CO 2 using the official testing method was 2.17%, and none exceeded the PM 10 standard of 100 µg/m 3 . With monitoring over 37 days, the daily noncompliance rate for CO 2 was 50.4% and the daily noncompliance rate for PM was 13.8%. Conclusions: When the official test method evaluates the indoor air at daycare centers one day per year, the results may not represent actual indoor air quality over a longer period of time. Real-time monitoring devices could be an alternative for managing indoor air quality.