김준섭(J.S. Kim),김규철(K.C. Kim),김기혁(G.H. Kim),장성철(S.C. Jang),우남섭(N.S. Woo),김영주(Y.J. Kim) 대한기계학회 2013 대한기계학회 춘추학술대회 Vol.2013 No.12
This study have goal with conceptual design for offshore structures of high pressure drop control valve for localization valve for development accomplished with flow analysis based on provision of ANSI B16.34, ANSI B16.10, ANSI B16.25 In order to localize the Offshore structures high pressure drop control valve. This study is numerical analysis for zambil offshore project of high pressure drop control valve. The solver which ANSYS workbench used for offshore structures analysis. The working fluids assumed the glycerin(C3H8O3). The structural analysis used ANSYS which is a commercial code. Stress analysis result of internal pressure in valve showed lower than yield strength. This is expect to need more detail design and verification for stem and disk structure.
장성철(S. C. Jang),서경호(G. H. Seo),박태수(T. S. Park),이재웅(J. W. Lee),최경관(G K. Choi),이용우(Y. W. Lee) 한국생산제조학회 2010 한국공작기계학회 추계학술대회논문집 Vol.2010 No.-
In this study, the development of collector system for high efficiency exhausted. The aim of this study is to remove crack on a ventilation device at the suction part of plants factory, and the main point is making optimum configuration by improving an existing collector system Finally, the improved high efficiency exhausted was designed.