http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
이한보람,Jaemin Kim,김형준,Woo-Hee Kim,Jeong Won Lee,황인찬 한국물리학회 2010 THE JOURNAL OF THE KOREAN PHYSICAL SOCIETY Vol.56 No.1
The effects of plasma on the degradation of the deposition blocking layer during area-selective atomic layer deposition were investigated. Co atomic layer deposition (ALD) processes were developed by using Co(iPr-AMD)2 (bis(N,N0-diisopropylacetamidinato)cobalt(II)) as a precursor, and two different reactants, NH3 gas for thermal ALD (TH-ALD) and NH3 plasma for plasma-enhanced ALD (PE-ALD). TH- and PE-ALD were applied to area selective ALD (AS-ALD) by using an octadecyltrichlorosilane (OTS) self-assembled monolayer (SAM) as a blocking layer. Both ALD processes produced pure Co films with resistivities as low as 50 µΩcm. For PE-ALD, however, no selective deposition was achieved due to a degradation of the OTS hydrophobicity caused by the NH3 plasma exposure. The effects of the plasma on the blocking efficiency of SAM were studied.
CaO-SiO<sub>2</sub>-Al<sub>2</sub>O<sub>3</sub>-MgO 슬래그와 Cu-Ni합금 사이의 Ni 분배거동
한보람,손호상,Han, Bo-Ram,Sohn, Ho-Sang 한국자원리싸이클링학회 2015 資源 리싸이클링 Vol.24 No.1
본 연구는 건식제련법으로 폐 PCB를 처리하는 공정에서 슬래그 중 Ni의 용해거동에 대한 기초연구로서, CaO-$SiO_2-Al_2O_3$-MgO계 슬래그와 Cu-5 wt%Ni합금 사이의 Ni 분배거동을 1623~1823 K의 $CO_2$-CO 분위기 중에서 조사하였다. 평형산소분압이 증가할수록 Ni의 분배비는 선형적으로 증가하였으며, 이 결과로부터 Ni의 슬래그 중 용해반응은 다음과 같이 나타낼 수 있다. $$Ni(l)_{metal}+\frac{1}{2}O_2(g)NiO(l)_{slag}$$ 슬래그 중 염기성 산화물(CaO와 MgO)의 농도가 증가할수록 Ni의 분배비는 선형적으로 증가하였다. 그러나 반응 온도가 높을수록 Ni의 분배비는 선형적으로 감소하였다. 이러한 결과로부터 Ni의 분배비에 미치는 실험변수의 영향을 다중 회귀분석하여 다음과 같은 경험식을 얻었다. $${\log}L_{Ni}=0.4000{\log}P_{O2}-5.1{\times}10^{-4}T+0.3375\(\frac{X_{CaO}+X_{MgO}}{X_{SiO2}}\)$$ To obtain the fundamental information on the dissolution of nickel into the slag in the pyrometallurgical processes for treatment of wasted PCB, the distribution ratios of nickel between CaO-$SiO_2-Al_2O_3$-MgO slag and copper-5 wt%Ni alloy were measured at 1623 K to 1823 K under a controlled $CO_2$-CO atmosphere. The distribution ratio of Ni increased linearly with increasing oxygen partial pressure. Therefore, the dissolution reaction of nickel into the slags could be described by the following equation; $$Ni(l)_{metal}+\frac{1}{2}O_2(g)NiO(l)_{slag}$$ The distribution ratio of Ni increased linearly with increasing content of basic oxides(CaO and MgO) in slag. However, the distribution ratio of Ni decreased linearly with increasing temperature. From these results, the empirical equation of distribution ratio of Ni was obtained by the following equation from the analysis of experimental conditions by multiple regression. $${\log}L_{Ni}=0.4000{\log}P_{O2}-5.1{\times}10^{-4}T+0.3375\(\frac{X_{CaO}+X_{MgO}}{X_{SiO2}}\)$$
경찰공무원의 외상성 사건과 PTSD 증상 및 우울의 관계: 직무스트레스의 조절효과
한보람,김정규 한국임상심리학회 2014 Korean Journal of Clinical Psychology Vol.33 No.3
This study attempted to investigate the relation of police officer's traumatic events and Post traumatic Stress Disorder (PTSD) symptoms, depression, and moderating effect of job stress. The Traumatic event scale, Impact of Event Scale-Revised (IES-R), Korean-Beck Depression Inventory (BDI), and Job stress scale were administered to 500 police officers working in Gyeonggi-do. To determine the relation of Police officer's traumatic events and Post traumatic Stress Disorder (PTSD) symptoms, depression, and interaction effects, multiple regressions and hierarchical multiple regressions were run using obtained data. Results indicated that experience of traumatic event events caused PTSD symptoms and depression. In particular, subjective amount of shock of traumatic events was a stronger predictor than the number of traumatic events in PTSD symptoms and depression. Results also showed a moderating effect of job stress in relation to traumatic events and Post traumatic Stress Disorder (PTSD) symptoms, depression. Finally, implication and limitation of this study were discussed.
포스터 15 : 비예기항체 선별검사의 자동화 장비와 반자동화 장비 사용의 유용성
한보람 대한임상병리사협회 2013 임상수혈검사학회 발표자료집 Vol.2013 No.-
배경(Background): 비예기항체 선별검사는 수혈부작용으로부터 환자를 보호하고 안전한 수혈을 위해 수혈 전 행하는 기본 검사이다. 최근 혈액은행 분야에서도 자동화가 진행됨에 따라국내에서도 자동화 장비를 사용하기 시작하였다. 본원에서는 수혈의 안정성을 위하여, 수작업에서 오는 오류를 줄이며 보다 신속, 정확한 비예기항체 검출을 하기 위해 자동화 장비인AutoVue Innova Ortho장비 사용과 함께 양성 검체의 재검 시 사용하는 반자동화 장비 BioVueSystem을 병행하여 사용하고 있다. 이에 두 장비 사용의 유용성을 평가하고자 한다. 방법(Methods): 2013년 4월부터 2013년 10월 본원 검사실에 의뢰된 비예기항체 선별검체는 모두 자동화 장비인 AutoVue Innova Ortho, 시약은 0.8% Selectogen I, II (Ortho-ClinicalDianostics) 사용하여 비예기항체 선별검사을 시행한다. 검사 결과 1Positive 이하인 144건의 양성 검체를 대상으로 재검 시 사용하는 반자동화 장비인 BioVue System, 시약은 3% SelectogenI, II (Ortho-Clinical Dianostics)을 사용하여 비교 검사 하였다. 결과(Results): 자동화 장비인AutoVue Innova Ortho장비에서 1 Positive이하의 양성률은 1.17%(144/12,304)보였다. AutoVue Innova Ortho장비에서 양성 결과를 보인 144건을 대상으로 반자동화 장비인BioVue System 재검 시 1 Positive이하의 양성률은 0.25%(31/12,304)를 보였다. AutoVue Innova Ortho장비에서Trace결과가 BioVue System 재검 시 Negative로 보고된 경우는 0.74%(92/12,304)에 달했다. 고찰(Discussion): 수혈예정자의 비예기항체 선별검사가 일반화 되어가고 검사량의 증가와 수작업으로 인한 오류를 최소화하기 위해 자동화 장비에 대한 요구가 증대되고 도입이 시행되고 있다. 하지만 혈구의 제조 과정에서 오는 차이와 Cell의 농도차이, BLISS사용 유무에 따라 민감도의 차이는 보일 수 있다. 이에 보다 정확한 비예기항체 선별검사 결과를 위해서 자동화장비와 양성 검체의 재검을 위한 반자동화 장비의 병행은 사용을 추천한다.
Al<sub>2</sub>O<sub>3</sub>-CaO-SiO<sub>2</sub>-MgO계 슬래그 중 Cu의 용해도
한보람,김응진,손호상,Han, Bo-Ram,Kim, Eung-Jin,Sohn, Ho-Sang 한국자원리싸이클링학회 2014 資源 리싸이클링 Vol.23 No.1
본 연구에서는 폐 PCB의 주성분인 Cu와 $CaO-SiO_2-Al_2O_3-MgO$계 슬래그의 평형실험에 의해 Cu의 용해도에 대하여 조사하였다. 1673 K~1825 K 범위에서 일정한 비율로 미리 용융된 4원계 슬래그와 Cu를 흑연 도가니에 각각 20 g 장입한 후, 10시간동안 평형 을 유지하였다. 분위기 중의 산소분압은 CO가스와 Ar가스의 비율을 조절하여 $10^{-17.23}{\sim}10^{-15.83}$ atm 범위로 제어하였다. 평형산소 분압과 염기도 및 MgO 농도가 증가할수록 슬래그 중 Cu의 농도는 증가하였다. 그리고 반응 온도가 높을수록 슬래그 중의 Cu의 농도는 감소하였다. 슬래그 중으로 용해되는 Cu의 반응은 발열반응이다. In this study, the solubility of Cu, which is a main metal component of wasted PCB, in $CaO-SiO_2-Al_2O_3-MgO$ slag system was investigated. Each 20 grams of Cu chips and the quaternary slag manufactured was placed in an carbon crucible and melted for 10 hours in the temperature between 1673 K and 1825 K to confirm the equilibrium state. The oxygen partial pressure was controlled by the ratio of CO and Ar gas in the range of $10^{-17.23}$ to $10^{-15.83}$ atm. The concentration of Cu in the slag increased with increasing oxygen partial pressure, slag basicity, and MgO content in the slag. The concentration of Cu in the slag decreased with increasing temperature. The Cu dissolution reaction in the slag is an exothermic reaction.