RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • SCOPUSKCI등재

        민감도법에 의한 최적블랭크 형상 설계에 관한 연구

        심현보,손기찬,Sim, Hyeon-Bo,Son, Gi-Chan 대한기계학회 2000 大韓機械學會論文集A Vol.24 No.1

        In this study, a method of optimal blank design using the sensitivity analysis has been proposed. To get sensitivity a well-known commercial code PAM-STAMP has been used. In order to verify this method, formings of square cup, clover shaped cup and L shaped cup have been chosen as the examples. With the predicted optimal blank both computer simulation and experiment are performed. Excellent agreements are recognized between the numerical results and the target contour shapes. Through the investigation, the proposed systematic method of optimal blank design is found to be effective in the design of the deep drawing process.

      • DR wireless detector를 이용한 abdomen upright 검사 시 grid 사용에 따른 cut-off 현상을 줄일 수 있는 최적의 X선 입사각도 고찰

        심현보(Hyeon-Bo SIM),정지상(Ji-Sang Jung):안치복(Chi-Bok Ahn),박순규(Sun-Kyu Park),임재식(Jae-Sik Lim) 대한영상의학기술학회 2017 대한영상의학기술학회 논문지 Vol.2017 No.1

        목 적:이동형 침대에서 abdomen upright 검사 시 obese patient 경우 DR wireless detector에 grid를 사용하여 검사를 진행한다. 이때 X선 입사각도와 detector의 기하학적 위치에 따라 cut-off 현상이 발생 할 수 있으며, 이러한 cut-off 현상의 영향을 줄일 수 있는 최적의 X선 입사각도의 범위를 알아보고자 한다. 대상 및 방법:X선 발생장치와 DR wireless detector 에 parallel gird (ratio 10:1)를 사용한 후 복부팬텀을 이용하여 abdomen upright 검사를 재현 하였다. 관전압은 70 kVp, 관전류는 20 mAs, SID는 130 cm로 촬영 조건을 설정하고 detector는 length로 위치하였다. 실험1)튜브 각도 0˚기준으로 음극 방향으로 5˚증가하여 30˚까지 변화를 주었고 detector의 기하학적 변화는 팬텀의 횡단면에 90˚(수직)와 앞뒤로 ±10˚,±20˚ 기울어진 설정을 하였다. 실험2)튜브 각도 0˚기준으로 음극 방향으로 5˚증가하여 15˚까지 변화를 주었고 detector의 기하학적 변화는 팬텀의 관상면에 평행을 기준으로 옆으로 5˚, 10˚ 기울어진 설정을 하였다. detector의 기하학적 변화에 따라 튜브 각도를 각각 적용 시켰으며 획득된 영상은 방사선사 3명이 리커트척도를 이용한 육안적 평가와 Image J 프로그램을 이용한 동일한 관심영역의 신호 평균값 및 표준편차를 측정하였다. 측정된 값으로 대조도잡음비를 산출하여 영상을 비교하였고, 통계학적 검정은 Kruskal-wallis test 와 Mann-Whiteny와 대응표본 t검정으로 유의성을 분석하였다. 결 과:정량적인 평가는 실험1)의 대조도대 잡음비는 튜브 각도가 0˚/5˚/10˚/15˚/20˚/25˚/30˚일 때 평균 11.29/10.62/10.27/9.34/6.74/4.61/3.63로 통계적으로 유의한 차이가 있었다.(p〈0.05). 실험2)는 각각의 튜브 각도가 0˚/5˚/10˚/15˚일 때 평균 9.37/8.19/6.73/6.29 였지만 통계적으로 유의한 차이가 없었다.(p〉0.05). 실험1)에서 튜브 각도가 15˚에서 20˚ 사이에서 대조도대잡음비는 가장 크게 감소하였다. 정성적인 평가 결과에서 실험1)은 응답자의 평균 점수와 Kruskal-wallis test 순위 검정 결과 튜브 각도가 15˚/20˚일 때 평균 4.5점/2.8점, 순위 67.9/37.2 이였고 실험2)에서는 튜브 각도가 5˚/10˚일때 평균 3.6점/1.8점 순위 23.8/12.9로 각각 감소폭이 가장 컸다. Mann-Whiteny를 통한 사후 검정 결과 실험1)의 튜브 각도 15˚/20˚와 실험2)의 튜브 각도가 5˚/10˚는 통계적으로 유의하였다.(p〈0.05) 결 론:DR wireless detector에 gird(ratio 10:1)를 사용한 abdomen upright 검사에서 cut-off 현상은 튜브각도가 양극과 음극방향에서 15˚이상 주어지거나 detector가 피사체의 관상면에서 5˚이상 oblique하게 기울어진 경우 발생한다. 튜브각도는 수직입사에서 ±15˚이상 주지 않고 detector는 피사체의 관상면에 oblique하게 놓지 않는다면 cut-off 현상을 방지 할 수 있으므로 임상에서 환자 피폭과 영상의 질적인 측면에서 고려해야 할 사항이다. Purpose:If the abdomen is upright in the mobile bed and the obese patient is in the DR wireless detector, the grid is used for the examination. In this case, the cut-off phenomenon may occur depending on the X-ray incident angle and the geometrical position of the detector, and the range of the optimum X-ray incident angle that can reduce the influence of the cut-off phenomenon is investigated. Materials and Methods:We used a parallel gird (ratio 10: 1) to the X - ray generator and the DR wireless detector and then reproduced the abdomen upright test using abdominal phantom. The tube voltage was 70kVp, the tube current was 20mAs, and the SID was 130cm. Experiment 1) The tube angle was increased by 5 ° in the direction of the cathode to 0 °, and it was changed to 30 °. The geometrical change of the detector was set 90 ° (vertical) to the transverse section of the phantom and inclined ± 10 ° and ± 20 ° back and forth . Experiment 2) The tube angle was increased by 5 ° in the direction of the cathode by 0 ° and changed to 15 °. The geometric change of the detector was set at 5 ° and 10 ° to the side of the phantom parallel to the coronal plane. Tube angles were applied to each detector according to the geometric change of the detector. The acquired images were measured by means of a visual evaluation using the Rickert scale of three radiologists and the mean and standard deviation of the signals in the same area of interest using the Image J program. Statistical analysis was performed using the Kruskal-wallis test and Mann-Whiteny and the corresponding sample t-test for statistical significance. Result:In the quantitative evaluation, the contrast- to-noise ratio of Experiment 1) was 11.29 / 10.62 / 10.27 / 9.34 / 6.74 / 4.61 when the tube angle was 0˚ / 5˚ / 10˚ / 15˚ / 20˚ / 3.63, respectively (p 〈0.05). Experiment 2) showed an average 9.37 / 8.19 / 6.73 / 6.29 when the tube angle was 0˚ / 5˚ / 10˚ / 15˚, but there was no statistically significant difference (p〉 0.05). In Experiment 1), the contrast- to-noise ratio was the greatest at a tube angle between 15 ° and 20 °. In the qualitative evaluation results, the average score of the respondents and the Kruskal-wallis test rank test were 4.5 points / 2.8 points and 67.9 / 37.2 points respectively when the tube angle was 15˚ / 20˚, and in the Experiment 2) The average decrease was 3.6 points / 1.8 points and 23.8 / 12.9 points respectively. After the posttest by Mann-Whiteny, the tube angle of 15˚ / 20˚ in Experiment 1) and the tube angle of 5˚ / 10˚ in Experiment 2) were statistically significant (p 〈0.05) Conclusion:In the abdomen upright test using gird (ratio 10: 1) on the DR wireless detector, the cutoff phenomenon was observed when the tube angle was more than 15 ° in the direction of the anode and cathode, or when the detector was obliquely inclined more than 5 ° in the coronal plane of the subject Occurs. If the tube angle is not more than ± 15 ° in vertical incidence and the detector is not obliquely placed on the coronal surface of the subject, it can prevent the cut-off phenomenon. Therefore, it should be considered in terms of patient exposure and quality of the image

      • SCOPUSKCI등재

        원자력 주기기용 볼트 개폐구조물의 해석과 ANSYS를 이용한 전용 해석 프로그램의 개발

        전성문,서의권,심현보,김태환,이부윤,Jeon, Seong-Mun,Seo, Ui-Gwon,Sim, Hyeon-Bo,Kim, Tae-Hwan,Lee, Bu-Yun 대한기계학회 1998 大韓機械學會論文集A Vol.22 No.4

        Bolted opening structures is widely applied for class 1 machinery of nuclear plant with strict design requirement. As the shape of the bolted opening structure is non-axisymmetric due to the existence of stud bolts although it is almost axi-symmetric, 3D analysis is required to satisfy such kind of design requirements. Because as much as possible trial computations are need to get an optimal design condition in the limited period of basic design, an easy and fast analysis tool is useful in the design stage. In the paper, a transformation technique of non-axisymmetric problem into quasi-axisymmetric has been proposed based on the general purpose commercial code ANSYS. Both the pre-processor which incorporates the technique and prepares data and post-processor which prepares arranged results from the huge output of commercial code have been developed to help the design engineers.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼